Medical gas manifold

The medical gas manifold is a device that high-pressure gas from cylinders can be decompressed through the manifold before supply for patients. It includes oxygen manifold, carbon dioxide manifold, nitrous oxide manifold, nitrogen manifold, etc. They are all used for gas adjustment and supply.

AmcareMed gas manifold, also called gas cylinder manifold, is focused on gas complement and supply. Several cylinders gas is connected by valves and tubes to the manifold so that the cylinders can be inflated at the same time. Or after pressure reduced and regulated, the gas is transmitted by the pipeline to the specialized equipment of a hospital. This can ensure the pressure of gas resource is stable and adjustable, and continuous gas supply.AmcareMed medical gas manifolds are easy to install with other medical gas systems, such as oxygen generator, the gas outlet, and the medical air compressor.

AmcareMed medical gas manifolds include LCD display medical automatic manifold, semi automatic gas manifold system and LED automatic solenoid medical gas manifold. They can meet a variety of needs of the medical gas system.

1.LCD display medical automatic manifold

AmcareMed LCD type automatic medical gas manifold is fully automatic display information at LCD panel, all complying with HTM02-01, HTM2022, and C11. Both with digital and gauge pressure indication. Color display for easy reading.

Advantages:

1. Closed metal box, anti-interference.

2. Scene signal lights indicate the state, pressure gauge displays the pressure, and have the cylinder change alarm function.

3. Adopting pilot pressure differential control, accurate pressure control, and low failure rate.

4. When the circuit fails, the outlet is still out of gas, and both sides supply air at the same time. Built-in one-way valve can be repaired with gas.

5. The external remote alarm can provide alarm switch signal or analog signal (Central monitoring), the pressure alarm value can be set arbitrarily.

6. With temperature control (CO2, N2O) to prevent frosting and overheating.

7. The pipeline adopts the form of joint connection, which is more convenient for maintenance.

2.LED automatic solenoid medical gas manifold

AmcareMed LED automatic medical gas manifold is fully automatic and has pressure regulators with LED Display. Pressure unit provides a bar, Mpa or psi for measurement conversion. This series of the medical gas manifold adopts electronic switching control, copper integration structure of the dual-path design, stable pressure, large flow, flexible automatic switching and can also be manual. It provides stable inlet pressure for the secondary regulator of the ward building, and can also be directly supplied to the gas outlet. Under the working state, one way supplies gas and another way for standby. When the one-way gas pressure is lowered to the predetermined minimum value, the led automatic manifold can automatically switch to another way,  alternately supply medical gas, and continuously supply the ward building to provide uninterrupted supply of medical gases.

3.Semi automatic gas manifold system

AmcareMed Manual/Semi-Automatic Manifold Systems main using at small and medium hospitals. When using the medical gas oxygen manifold, several cylinders need to be connected to the manifold pipeline. The oxygen gas is first filtered and decompressed,  and then transported through the main pipe to the end of use.

Scroll to Top